PEM electrolysis water hydrogen production system experimental teaching tools hydrogen production equipment

PEM Electrolyzer-5cm*6cm

PEM Electrolyzer-7CM*7CM

PEM Electrolyzer-14cm*7cm

PEM Electrolyzer-30CM*17CM

PEM Electrolyzer-58*30cm

PEM Electrolyzer-76CM*42CM

Containerized Systems

Containerized Hydrogen Systems for Flexible & Scalable Deployment

At H2 Electrolyzer Maker, we provide containerized hydrogen production systems designed for fast deployment, modular scalability, and seamless integration with renewable energy sources. Our plug-and-play units house PEM electrolyzers, power electronics, cooling systems, and hydrogen purification equipment within a compact container, delivering a ready-to-operate hydrogen solution for industries, utilities, and energy developers worldwide.

Why Choose Our Containerized Systems?

Turnkey Solution

Pre-engineered and fully integrated systems reduce on-site construction and commissioning ti

Scalable & Modular

Start small and expand capacity by adding additional containers as your hydrogen needs grow.

Fast Deployment

Shipped and installed quickly for projects requiring rapid hydrogen availability.

Safe & Reliable

Built to international safety and performance standards, ensuring dependable hydrogen supply.

System Features

  • PEM Electrolyzer Technology – High-efficiency hydrogen production with quick response times.
  • Containerized Housing – Weatherproof and insulated for operation in harsh environments.
  • Integrated Balance of Plant – Includes water treatment, power supply, cooling, and safety systems.
  • Remote Monitoring – IoT-enabled for performance tracking, predictive maintenance, and optimization.
  • Flexible Power Input – Compatible with solar PV, wind, hydropower, and grid connections.

Applications Across Industries

  • Renewable Energy Projects – Converting excess solar and wind power into storable hydrogen.
  • Industrial Decarbonization – Supplying green hydrogen for refineries, steel plants, and chemical production.
  • Transportation & Mobility – On-site hydrogen generation for fueling stations.
  • Off-Grid & Remote Operations – Reliable clean energy supply for mining, islands, and rural communities.

Get a Quote for Your Containerized Hydrogen Project

Looking for a fast, scalable, and cost-effective hydrogen solution? Our containerized systems make hydrogen production smarter, cleaner, and easier to deploy.

Our Products

XRA Series

Product Model

XRA-WE150ML

XRA-WE300ML

XRA-WE600ML

XRA-WE900ML

Hydrogen production capacity

150 ml/min

300 ml/min

600 ml/min

900 ml/min

Oxygen production capacity

75 ml/min

150 ml/min

300 ml/min

450 ml/min

Effective Area of MEA

50×40 mm

50×40 mm

50×40 mm

50×40 mm

No. of cells

1 cell

2 cells

5 cells

7 cells

Working current (DCA)

20

20

20

20

Working voltage (DCV)

1.8

3.6

9

12.6

Oxygen side water inlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side water outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Hydrogen side gas outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Hydrogen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Water pump flow

0.13 L/min

0.26 L/min

0.65 L/min

0.91 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

85×87.5×25.1

85×87.5×30.2

85×87.5×49.5

85×87.5×59.7

XRB Series

Product Model

XRB-WE600ML

XRB-WE1000ML

XRB-WE1600ML

XRB-WE2000ML

Hydrogen production capacity

600 ml/min

1000 ml/min

1600 ml/min

2000 ml/min

Oxygen production capacity

300 ml/min

500 ml/min

800 ml/min

1000 ml/min

Effective Area of MEA

50×60 mm

50×60 mm

50×60 mm

50×60 mm

No. of cells

3 cells

5 cells

8 cells

10 cells

Working current (DCA)

30

30

30

30

Working voltage (DCV)

5.4

9

14.4

18

Oxygen side water inlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side water outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Hydrogen side gas outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Hydrogen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Water pump flow

0.6 L/min

1 L/min

1.6 L/min

2 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

101×96×40.3

101×96×50.5

101×96×65.8

101×96×76

XRB1 Series

Product Model

XRB1-WE600ML

XRB1-WE1000ML

XRB1-WE1600ML

XRB1-WE2000ML

Hydrogen production capacity

600 ml/min

1000 ml/min

1600 ml/min

2000 ml/min

Oxygen production capacity

300 ml/min

500 ml/min

800 ml/min

1000 ml/min

Effective Area of MEA

50×60 mm

50×60 mm

50×60 mm

50×60 mm

No. of cells

2 cells

4 cells

6 cells

7 cells

Working current (DCA)

45

45

45

45

Working voltage (DCV)

3.6–5

7.2–10

10.8–15

12.6–17.5

Oxygen side water inlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side water outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Hydrogen side gas outlet

1/8 inch

1/8 inch

1/8 inch

1/8 inch

Oxygen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Hydrogen side pressure resistance

0–3 MPa

0–3 MPa

0–3 MPa

0–3 MPa

Water pump flow

0.4 L/min

0.8 L/min

1.2 L/min

1.4 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

101×96×39.2

101×96×49.5

101×96×59.7

101×96×64.8

XRC Series

Product Model

XRC-WE2000ML

XRC-WE3000ML

XRC-WE4000ML

XRC-WE5000ML

Hydrogen production capacity

2000 ml/min

3000 ml/min

4000 ml/min

5000 ml/min

Oxygen production capacity

1000 ml/min

1500 ml/min

2000 ml/min

2500 ml/min

Effective Area of MEA

70×70 mm

70×70 mm

70×70 mm

70×70 mm

No. of cells

4 cells

6 cells

8 cells

10 cells

Working current (DCA)

73.5

73.5

73.5

73.5

Working voltage (DCV)

7.2–10

10.8–15

14.4–20

18–25

Oxygen side water inlet

1/4 inch

1/4 inch

1/4 inch

1/4 inch

Oxygen side water outlet

1/4 inch

1/4 inch

1/4 inch

1/4 inch

Hydrogen side gas outlet

1/4 inch

1/4 inch

1/4 inch

1/4 inch

Oxygen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Hydrogen side pressure resistance

0–3 MPa

0–3 MPa

0–3 MPa

0–3 MPa

Water pump flow

1.2 L/min

1.8 L/min

2.4 L/min

3 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

125×146×69.4

125×146×79.6

125×148×91.9

125×146×100

XRD Series

Product Model

XRD-WE0.5M

XRD-WE1M

XRD-WE1.5M

XRD-WE2M

Hydrogen production capacity

0.5 Nm³/h

1 Nm³/h

1.5 Nm³/h

2 Nm³/h

Oxygen production capacity

0.25 Nm³/h

0.5 Nm³/h

0.75 Nm³/h

1.5 Nm³/h

Effective Area of MEA

140×70mm

140×70mm

140×70mm

140×70mm

No. of cells

9 cells

17 cells

25 cells

34 cells

Working current (DCA)

147

147

147

147

Working voltage (DCV)

16.2-22.5

30.6-42.5

45-62.5

61.2-85

Oxygen side water inlet

3/8 inch

3/8 inch

3/8 inch

3/8 inch

Oxygen side water outlet

3/8 inch

3/8 inch

3/8 inch

3/8 inch

Hydrogen side gas outlet

3/8 inch

3/8 inch

3/8 inch

3/8 inch

Oxygen side pressure resistance

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

0–0.5 MPa

Hydrogen side pressure resistance

0–3 MPa

0–3 MPa

0–3 MPa

0–3 MPa

Water pump flow

5.4 L/min

10.2 L/min

15 L/min

20.4 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

175×280×120.3

175×280×161.5

175×280×202.7

175×280×249.1

XRE Series

Product Model

XRE-WE2.5M

XRE-WE3M

XRE-WE3.5M

XRE-WE4M

Hydrogen production capacity

2.5 Nm³/h

3 Nm³/h

3.5 Nm³/h

4 Nm³/h

Oxygen production capacity

1.25 Nm³/h

1.5 Nm³/h

1.75 Nm³/h

2 Nm³/h

Effective Area of MEA

200×130mm

200×130mm

200×130mm

200×130mm

No. of cells

16 cells

19 cells

22 cells

25 cells

Working current (DCA)

390

390

390

390

Working voltage (DCV)

28.8-40

34.2-47.5

39.6-55

45-62.5

Oxygen side water inlet

50.5chuck

50.5chuck

50.5chuck

50.5chuck

Oxygen side water outlet

50.5chuck

50.5chuck

50.5chuck

50.5chuck

Hydrogen side gas outlet

3/8 inch

3/8 inch

3/8 inch

3/8 inch

Oxygen side pressure resistance

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

Hydrogen side pressure resistance

0–3 MPA

0–3 MPA

0–3 MPA

0–3 MPA

Water pump flow

28.8 L/min

34.2 L/min

39.6 L/min

45 L/min

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

386×387×177.4

386×387×192.8

386×387×208.3

386×387×223.7

XRF Series

Product Model

XRF-WE5M

XRF-WE8M

XRF-WE10M

XRF-WE15M

Hydrogen production capacity

5 Nm³/h

8 Nm³/h

10 Nm³/h

15 Nm³/h

Oxygen production capacity

2.5 Nm³/h

4 Nm³/h

5 Nm³/h

7.5 Nm³/h

Effective Area of MEA

300×170mm

300×170mm

300×170mm

300×170mm

No. of cells

17 cells

27 cells

34 cells

50 cells

Working current (DCA)

765

765

765

765

Working voltage (DCV)

30.6-42.5

48.6-67.5

61.2-85

90-125

Oxygen side water inlet

50.5chuck

50.5chuck

50.5chuck

50.5chuck

Oxygen side water outlet

50.5chuck

50.5chuck

50.5chuck

50.5chuck

Hydrogen side gas outlet

3/4 inch×2

3/4 inch×2

3/4 inch×2

3/4 inch×2

Oxygen side pressure resistance

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

Hydrogen side pressure resistance

0–3 MPA

0–3 MPA

0–3 MPA

0–3 MPA

Water pump flow

47.6 L/min (the oxygen outlet pressure should be ≥0.1Mpa)

75.6 L/min (the oxygen outlet pressure should be ≥0.1Mpa)

95.2 L/min (the oxygen outlet pressure should be ≥0.1Mpa)

140 L/min (the oxygen outlet pressure should be ≥0.1Mpa)

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

516×495×251.75

516×495×315.25

516×495×359.7

516×495×461.3

XRG Series

Product Model

XRG-WE20M

XRG-WE30M

XRG-WE40M

XRG-WE50M

Hydrogen production capacity

20 Nm³/h

30 Nm³/h

40 Nm³/h

50 Nm³/h

Oxygen production capacity

10 Nm³/h

15 Nm³/h

20 Nm³/h

25 Nm³/h

Effective Area of MEA

420×420mm

420×420mm

420×420mm

420×420mm

No. of cells

20 cells

30 cells

40 cells

50 cells

Working current (DCA)

2646

2646

2646

2646

Working voltage (DCV)

36-50

36-50

72-100

90-125

Oxygen side water inlet

77.5chuck

77.5chuck

77.5chuck

77.5chuck

Oxygen side water outlet

77.5chuck

77.5chuck

77.5chuck

77.5chuck

Hydrogen side gas outlet

1inch×2

1inch×2

1inch×2

1inch×2

Oxygen side pressure resistance

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

Hydrogen side pressure resistance

≤1.6MPA

≤1.6MPA

≤1.6MPA

≤1.6MPA

Water pump flow

77.15 L/min (the oxygen outlet pressure should be ≥0.15Mpa)

115.73 L/min (the oxygen outlet pressure should be ≥0.15Mpa)

154.3 L/min (the oxygen outlet pressure should be ≥0.15Mpa)

192.89 L/min (the oxygen outlet pressure should be ≥0.15Mpa)

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

746×860×321.5

746×860×383

746×860×444.5

746×860×506

XRH Series

Product Model

XRH-WE80M

XRH-WE100M

XRH-WE200M

XRH-WE250M

Hydrogen production capacity

80 Nm³/h

100 Nm³/h

200 Nm³/h

250 Nm³/h

Oxygen production capacity

40 Nm³/h

50 Nm³/h

100 Nm³/h

125 Nm³/h

Effective Area of MEA

760×420mm

760×420mm

760×420mm

760×420mm

No. of cells

40 cells

51 cells

102 cells

127 cells

Working current (DCA)

4788

4788

4788

4788

Working voltage (DCV)

72-100

91.8-127.5

183.6-255

228.6-317.5

Oxygen side water inlet

130chuck

130chuck

130chuck

130chuck

Oxygen side water outlet

130chuck

130chuck

130chuck

130chuck

Hydrogen side gas outlet

RC 1inch×2

RC 1inch×2

RC 1inch×2

RC 1inch×2

Oxygen side pressure resistance

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

0–0.5 MPA

Hydrogen side pressure resistance

≤1.6MPA

≤1.6MPA

≤1.6MPA

≤1.6MPA

Water pump flow

279.22 L/min (the oxygen outlet pressure should be ≥0.2Mpa)

356.01 L/min (the oxygen outlet pressure should be ≥0.2Mpa)

712.01 L/min (the oxygen outlet pressure should be ≥0.2Mpa)

886.53 L/min (the oxygen outlet pressure should be ≥0.2Mpa)

Working temperature (°C)

40–60

40–60

40–60

40–60

Energy consumption

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

≤4.4 kWh/Nm³

Service life (ultrapure water ≥15MΩ)

≥50,000 H

≥50,000 H

≥50,000 H

≥50,000 H

Size (L×W×H mm)

936×1104×540.5

936×1104×605.4

936×1104×906.3

936×1104×1053.8

Scroll to Top